Display

2.31 inch 320X240 high-definition color screen display

Detection method

Built in pump suction, flow 500 ml / min.

Datalogging

10000 samples, can be transferred to PC through USB

Detection accuracy

Less than 3% (F.S.)

Linearity

Less than 2%

Repeatability

Less than 2%

Alarm mode

Sound and light alarm, vibration alarm, visual alarm

Response time: T90

20 seconds

Recovery time

< 30 seconds

Operating power

DC3.6V

Battery capacity

3.6VDC, 4500mA

Charger

USB Charger

Working temperature

- 40 to +70

Working humidity

0-95% RH

Sample gas temperature

-40 to C20+70

Explosion-proof type

EX ia IIC T4

Protection degree

IP65Dustproof, waterproof splash

Dimension

160×70×28mm (L×W×H)

Weight

300g

Standby hours

8 to 10

Time to fully charge

4 hours

 

Sr. No.

Application

Model

Detection Gas

Range

Resolution

1.

Bio Gas

PGABG4

Carbon dioxide (CO2),

CO2: 0-20% vol

CO2: 1 % / 0.1 % / 0.01%

 

 

 

Oxygen (O2),

O2: 0-30% vol

O2: 1 % / 0.1 % / 0.01%

 

 

 

Methane (CH4),

CH4: 0-100% lel

CH4: 1 % / 0.1 % / 0.01%

 

 

 

Hydrogen Sulphide (H2S)

H2S: 0-2000 ppm

H2S: 1 ppm

2.

Bio Gas

PGABG3

Carbon dioxide (CO2)

CO2: 0-20% vol

CO2: 1 % / 0.1 % / 0.01%

 

 

 

Methane (CH4),

CH4: 0-100% lel

CH4: 1 % / 0.1 % / 0.01%

 

 

 

Hydrogen Sulphide (H2S)

H2S: 0-2000 ppm

H2S: 1 ppm

3.

Bio Gas

PGABG2

Methane (CH4),

CH4: 0-100% lel

CH4: 1 % / 0.1 % / 0.01%

 

 

 

Hydrogen Sulphide (H2S)

H2S: 0-2000 ppm

H2S: 1 ppm

4.

Cold Storages

PGACS3

Oxygen (O2)

0 – 30 % vol

O2: 1 % / 0.1 % / 0.01%

 

 

 

Carbon dioxide (CO2)

0 – 20 % vol

CO2: 1 % / 0.1 % / 0.01%

 

 

 

Ethylene (C2H4)

0 – 2000 ppm

C2H4: 1 ppm

5.

Cold Storages

PGACS2A

Oxygen (O2)

0 – 30 % vol

O2: 0.1 % / 0.1 % / 0.01%

 

 

 

Ethylene (C2H4)

0 – 2000 ppm

C2H4: 1 ppm

6.

Cold Storages

PGACS2B

Carbon dioxide (CO2)

0 – 20 % vol

CO2: 1 % / 0.1 % / 0.01%

 

 

 

Ethylene (C2H4)

0 – 2000 ppm

C2H4: 1 ppm

7.

Cold Storages

PGACS2C

Carbon dioxide (CO2)

0 – 20 % vol

CO2: 1 %/ 0.1% / 0.01%

 

 

 

Oxygen (O2)

0 – 30 % vol

O2: 1 % / 0.1 % / 0.01%

 

Other Products in 'Portable Gas Analyzers' category



Back to top


RFQ Request For Quotation
Get Quotes For Your Buying Requirement. Tell Suppliers What You Need.
I agree to abide by all the Terms and Conditions of tradeindia.com
trade india member
CHEMTRON SCIENCE LABORATORIES PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.