Call Us07971891462( PIN:530)
Smart Sensor Module For Cold Rooms

Smart Sensor Module For Cold Rooms

Product Details:

X

Product Description

With huge experience and knowledge in this field, we manufacture and export a quality tested Smart Sensor Module For Cold Rooms to our clients. This item is made by using high quality required materials with the help of advanced technology. It is utilized in extreme cold climates for disabling the fresh air damper.  Offered Smart Sensor Module is quality tested by team of quality checkers on different parameters to make sure its quality. Apart from this, customers can avail the same from us at rock bottom rates.

General

Supply

24 V DC, single phase, 50 Hz

Wattage

8W

Dimensions

200mm x 120 x 75mm

Weight

400gm

Communication

RS 485 RTU (2 wire config)

Inputs (4 + 8)

4 RTD and 8 Analog 4-20 mA / 0-10V DC

Operating Temperature and Humidity

0 - 60°C and 0 - 95% RH for the unexposed parts

Ambient Temperature Sensor

Operating Principle

Band Gap

Measuring Range

0-50 ⁰ C

Accuracy

0.1°C

Response Time

5 seconds

Resolution

0.1°C

Output Signal

Digital SPI

Pulp Temperature Sensor

Operating Principle

PT 100 4 wire configuration

Measuring Range

0-50 ⁰ C

Accuracy

0.1°C

Response Time

5 seconds

Resolution

0.1°C

Output Signal

Resistance

RH Sensor

Operating Principle

Capacitive

Measuring Range

0-98 %

Accuracy

1%

Response Time

5 seconds

Resolution

1%

Output Signal

Digital SPI

Carbondioxide Sensor

Operating Principle

NDIR

Weight

2 kg

Exterior Finish

Powder Coating (RAL-7035)

Power Chord

3-PIN PLUG, 1.5Mtr

Power Chord

3-PIN PLUG, 1.5Mtr

Power Chord

3-PIN PLUG, 1.5Mtr

 General Specifications:

  • Dimensions: 100 * 70 * 50 mm
  • Weight: 200g
  • Enclosure: IP 65
  • Calibration: Span, Zero
  • Input voltage: 24V DC
  • Signal Output: 0-10 VDC / 0-5VDC / 4-20 mA
  • Output Linearity: Linear

Ammonia Transmitter 
  • Measurement range: 0-500 ppm
  • Sensing method: Electrochemical
  • Resolution: 0.1ppm
  • Repeatability: 1% of Signal
  • T90 Response Time: <140 seconds
CO2 Transmitter
  • Measurement range: 0-5 %, 0-10%
  • Sensing method: NDIR
  • Resolution: 0.1%
  • Repeatability: 1% of Signal
  • T90 Response Time: <120 seconds
Ethylene Transmitter
  • Measurement range: 0-200 ppm
  • Sensing method: Electrochemical
  • Resolution: 1ppm
  • Repeatability: 1% of Signal
  • T90 Response Time: <180 seconds
H2S Transmitter
  • Measurement range: 0-200 / 0-1000 / 0-2000 ppm
  • Sensing method: Electrochemical
  • Resolution: 1ppm
  • Repeatability: 1% of Signal
  • T90 Response Time: <180 seconds
Methane Transmitter
  • Measurement range: 0-100% LEL
  • Sensing method: Electrochemical
  • Resolution: 0.1% LEL
  • Repeatability: 1% of Signal
  • T90 Response Time: <180 seconds
Oxygen Transmitter
  • Measurement range: 0-30%
  • Sensing method: Electrochemical
  • Resolution: 0.1%
  • Repeatability: 1% of Signal
  • T90 Response Time: <120 seconds


Back to top


RFQ Request For Quotation
Get Quotes For Your Buying Requirement. Tell Suppliers What You Need.
I agree to abide by all the Terms and Conditions of tradeindia.com
trade india member
CHEMTRON SCIENCE LABORATORIES PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.